Language Selection

YOU ARE USING THE CNPHI QA SYSTEM (LIBERTY)
Français

Molecular Detection by RT-PCR

<<Return to Laboratory

Requisition Forms

Reference Details

Description:

Molecular detection of Hepatitis E virus by Real Time and conventional RT-PCR.

Test Category:
Molecular Detection
Pathogen:
Hepatitis E virus (HEV)
Illnesses and Diseases:
  • Hepatitis E
Specimen:

Serum or plasma sample. Minimum volume required for serum or plasma – 1.0 mL.

Collection Method:

Collect blood in serum separator tubes (SST) or EDTA tubes.

Specimen Processing, Storage and Shipping:

Store samples frozen until shipped for testing. Ship frozen on dry ice.

Transportation of Dangerous Goods:

Shipping of specimens shall be done by a TDG certified individual in accordance with TDG regulations. For additional information regarding classification of specimens for the purposes of shipping, consult either Part 2 Appendix 3 of the TDG Regulations or section 3.6.2 of the IATA Dangerous Goods Regulations as applicable.

Patient Criteria:

Suspected Hepatitis E virus infection. Serology results must show markers to the Hepatitis E virus.

Accompanying Documentation:

Completed Molecular and Immuno Diagnostics on Hepatitis requisition including sender name, address and telephone number. Patient name or identifier (referring specimen lab #), date of birth, suspected exposure, test(s) requested. Type of specimen and date collected. If possible, include the clinical history and lab results that have already been done at local or provincial laboratories.

Comments:
Methods and Interpretation of Results:

Conventional and Real Time PCR with several primer/probe sets.

Turnaround Time:

19 calendar days.

Contact:
Phone #: (204) 789-6062
Fax: (204) 789-2082
References:
  1. Jothikumar N, Cromeans TL, Robertson BH, Meng XJ, Hill VR. A broadly reactive one-step real-time RT-PCR assay for rapid and sensitive detection of hepatitis E virus. J Virol Methods. 2006;131(1):65-71.
  2. Inoue J, Takahashi M, Yazaki Y, Tsuda F, Okamoto H. Development and validation of an improved RT-PCR assay with nested universal primers for detection of hepatitis E virus strains with significant sequence divergence. J Virol Methods. 2006 Nov;137(2):325-33.
Guidelines: