Language Selection

YOU ARE USING THE CNPHI QA SYSTEM (LIBERTY)
Français

Viral Capsid Antigen (VCA) Confirmatory Immunofluorescence Assay (IFA) - IgG

<<Return to Search Results

Requisition Forms

Reference Details

Description:

Confirmation of Epstein-Barr Virus (EBV) Viral Capsid Antigen (VCA) by immunofluorescence assay (IFA) - IgG

Test Category:
Serology
Pathogen:
Epstein-Barr virus (EBV)
Illnesses and Diseases:
  • Infectious mononucleosis
Specimen:

Serum. The minimum volume required is 200 uL. Please note that CSF specimens are not normally processed for serology. Contact lab for more information.

Collection Method:

Collect blood in serum separator tubes (SST)

Specimen Processing, Storage and Shipping:

Do not freeze and thaw sera. Specimens may be stored and shipped to NML within 48h of sample collection or must be stored and shipped frozen.

Transportation of Dangerous Goods:

Shipping of specimens shall be done by a TDG certified individual in accordance with TDG regulations. For additional information regarding classification of specimens for the purposes of shipping, consult either Part 2 Appendix 3 of the TDG Regulations or section 3.6.2 of the IATA Dangerous Goods Regulations as applicable.

Patient Criteria:

Immunocompetent patients with equivocal routine serology results.

Accompanying Documentation:

Completed "Viral STI, Polyoma and Herpesvirus Testing" requisition form including sender lab name, address and telephone number, patient identifier, date of birth or age, sex, specimen reference #, type of specimen, date collected, test requested, reason for testing and any other relevant clinical information.

Comments:

N/A

Methods and Interpretation of Results:

Serum samples are tested by indirect immunofluorescence for IgG antibodies to EBV VCA using the Merifluor® EBV IgG IFA kit (1). HR1 Burkitt’s lymphocytic cells serve as the substrate (2). Results are reported as titre.

Turnaround Time:

Please contact lab to inquire about turn around time.

Contact:
Phone #: (204) 789-6024; HCMV: (204) 789-7042
Fax: (204) 789-2140; HCMV: (204) 789-5009
References:
  1. Meridian Biosciences, Inc. 2004. Merifluor® EBV IgG IFA Test Instructions.
  2. Henle, G and Henle, W. 1966. Immunofluorescence in cells derived from Burkitt's lymphoma. J. Bacteriology 91(3):1248- 1256.
Guidelines:
Related Information: